ZE03-NH3 Electrochemical Ammonia Detection Module

The ZE03-NH3 is a compact electrochemical module configured for ammonia detection. It provides a standard 0–100 ppm range, 1 ppm resolution, 3 V TTL UART concentration output and an amplified analog signal for OEM gas-detection equipment.

BrandWinsen
Sensing PrincipleElectrochemical
Target GasNH3
Product TypeElectrochemical Ammonia Sensor Module
Gas Sensing for OEM Integration

Product Overview

A pre-integrated electrochemical ammonia module with UART and analog outputs for portable and fixed gas detectors.

The module combines a replaceable gas-specific electrochemical sensing element, high-performance microprocessor and built-in temperature compensation in a standard ZE03 platform.

Calibrated concentration data can be read through UART, while the analog output provides the original amplified signal for custom processing and system calibration.

Designed for Reliable Integration

Key Features

Gas-Specific Configuration

Configured specifically for ammonia with a standard range of 0–100 ppm.

UART Concentration Output

Outputs concentration through a 3 V TTL serial interface at a default 9600 baud rate.

Analog Signal Output

Provides an amplified analog output with a listed range of 0.6–3 V.

Built-In Compensation

Integrated temperature sensing supports compensated gas concentration measurement.

Compact Standard Platform

The Ø23.3 × 31.2 mm module simplifies mechanical and electrical platform reuse.

Custom Range Support

The official manual notes that alternative detection ranges can be customized.

Typical Use Cases

Applications

Portable Gas Detectors
Fixed Gas Detection Systems
Industrial Safety Instruments
Environmental and Hazardous Gas Monitoring
Official Product Parameters

Technical Specifications

Parameter Specification
Model ZE03-NH3
Detected Gas Ammonia (NH3)
Detection Principle Three-electrode electrochemical
Standard Measurement Range 0–100 ppm
Resolution 1 ppm
Analog Voltage Output Range 0.6–3 V
Response Time (T90) ≤150 s
Working Voltage 5.0±0.1 V DC
Working Current <10 mA
Digital Output UART, 3 V TTL
Analog Output Original amplified sensor signal
Default Baud Rate 9600 bps
Operating Temperature -20°C to 50°C
Operating Humidity 15–90% RH, non-condensing
Storage Temperature -20°C to 50°C
Storage Humidity 15–90% RH, non-condensing
Dimensions Ø23.3 × 31.2 mm
Weight O2 version <25 g; other versions <15 g
Expected Life 2 years in clean air

Specifications are based on the official Winsen product page or product manual. Confirm the latest datasheet, calibration requirements, communication protocol and mechanical drawing before final product design.