MEs-CO Long-Life Electrochemical Carbon Monoxide Sensor

The Winsen MEs-CO is a fuel-cell electrochemical carbon monoxide sensor for long-life residential and commercial CO detection. It offers a 0–1000 ppm measurement range, 1 ppm resolution and a specified service life of 10 years.

BrandWinsen
Sensing PrincipleElectrochemical
Target GasCO
Product TypeElectrochemical CO Sensor
Gas Sensing for OEM Integration

Product Overview

A low-power, high-precision CO sensor developed for long-life alarms and fixed carbon monoxide monitoring equipment.

The sensing current is generated by the electrochemical oxidation-reduction reaction of carbon monoxide and is proportional to the gas concentration according to Faraday’s law.

Its wide linear range, stable repeatability and UL and EN 50291-1 certification information make it suitable for OEM carbon monoxide alarms and building-safety products.

Designed for Reliable Integration

Key Features

10-Year Design Life

Specified for a 10-year service life in air for long-life carbon monoxide alarm designs.

UL and EN 50291-1

Official product information lists UL and EN 50291-1 certification.

Linear Sensor Output

Supports concentration calculation through the external signal-conditioning and calibration circuit.

Stable Repeatability

Designed for consistent response across repeated exposure and recovery cycles.

Anti-interference Design

Provides selectivity for CO detection when used according to the datasheet and application guidance.

OEM Integration

Available for integration into fixed, portable, residential and industrial gas-detection products.

Typical Use Cases

Applications

Smart Home CO Alarms
Commercial Building Safety
Underground Garage Monitoring
Fire and Safety Monitoring
Official Product Parameters

Technical Specifications

Parameter Specification
Model MEs-CO
Detected Gas Carbon monoxide (CO)
Detection Principle Electrochemical fuel-cell type
Measurement Range 0–1000 ppm
Maximum Detecting Concentration 2000 ppm
Sensitivity 1.0–2.0 nA/ppm
Resolution 1 ppm
Response Time (T90) <30 s
Recommended Load Resistance 500 Ω / 1 kΩ / 2 kΩ
Repeatability <3% of output value
Output Linearity Linear
Zero Drift (-20°C to 40°C) ≤10 ppm
Temperature Range -20°C to 80°C
Humidity Range 15–90% RH
Pressure Range Standard atmosphere ±10%
Expected Life 10 years
Certification UL; EN 50291-1

Specifications are based on the official Winsen product page or product manual. Confirm the latest datasheet, calibration requirements, communication protocol and mechanical drawing before final product design.

Need More Information About the MEs-CO?

Contact us for the latest datasheet, model selection support, samples and OEM integration information.