The ZE33 is a dual-gas module for detecting carbon monoxide from incomplete combustion and methane leakage in household gas water heaters. It combines electrochemical CO sensing, semiconductor combustible-gas sensing, PWM output and audible-visible alarm functions.

BrandWinsen
Sensing PrincipleElectrochemical, Semiconductor
Target GasCO, CH4
Product TypeCO and CH4 Alarm Module
Gas Sensing for OEM Integration

Product Overview

A purpose-built CO and methane safety module for gas-water-heater leakage and incomplete-combustion alarms.

The module monitors CO generated by incomplete combustion while also detecting methane leakage, allowing one integrated board to address two major water-heater safety risks.

Defined alarm concentrations, PWM output and onboard sound and light indication support rapid integration into appliance control and alarm systems.

Designed for Reliable Integration

Key Features

Dual-Gas Detection

Detects both carbon monoxide and methane in one water-heater safety module.

Defined Alarm Levels

Provides two CO alarm levels and a methane alarm point based on percentage of LEL.

PWM Digital Output

Outputs a PWM signal for connection to the appliance controller.

Audible and Visual Alarm

Integrates sound and light alarm output functions.

Application-Specific Design

Developed for household gas-water-heater leakage and incomplete-combustion detection.

Customizable Module

Official product information notes customizable design support.

Typical Use Cases

Applications

Gas Water Heaters
Incomplete Combustion Alarms
Household Methane Leakage Detection
Appliance Safety Control
Official Product Parameters

Technical Specifications

Parameter Specification
Model ZE33
Detected Gases Carbon monoxide (CO), methane (CH4)
Detection Principles Electrochemical CO sensor; semiconductor combustible-gas sensor
Detection Range CO: 0–500 ppm; CH4: 0–5000 ppm
CO Alarm 1 250±50 ppm
CO Alarm 2 350±50 ppm
CH4 Alarm Concentration 8%±3% LEL
Interfering Gas Alcohol, etc.
Output PWM
Alarm Mode Audible and visual alarm
Working Voltage 5 V DC
Preheat Time CO: 30 s; CH4: 3 min
Response Time ≤60 s
Recovery Time ≤30 s
Working Temperature -10°C to 55°C
Working Humidity 15–90% RH, non-condensing
Storage Temperature -10°C to 55°C
Expected Life 5 years in air