MP810 Semiconductor Hydrogen Gas Sensor

The Winsen MP810 is a compact semiconductor hydrogen gas sensor using a metal-oxide sensitive layer and TO-5 package. It is designed for 100–3000 ppm H2 detection with high sensitivity, fast response and a simple external application circuit.

BrandWinsen
Sensing PrincipleSemiconductor
Target GasH2
Product TypeSemiconductor Hydrogen Sensor
Hydrogen Sensing for OEM Integration

Product Overview

A TO-5 semiconductor H2 sensor for compact hydrogen leakage detection in energy vehicles and hydrogen storage systems.

MP810 uses multilayer thick-film manufacturing with a heater and metal-oxide semiconductor sensing material on a miniature Al2O3 substrate.

Its conductivity changes with hydrogen concentration, allowing a simple external circuit to convert resistance variation into a concentration-related output signal.

Designed for Reliable Integration

Key Features

High H2 Sensitivity

Designed for responsive resistance change in the presence of hydrogen.

Fast Response

Suitable for hydrogen leakage warning applications requiring quick sensor reaction.

Compact TO-5 Package

Flat-surface semiconductor structure supports compact OEM layouts.

Simple Interface Circuit

Sensor conductivity can be converted to a usable signal with a straightforward external circuit.

Low Heater Power

Official specifications list heater consumption of ≤300 mW.

Energy-Safety Applications

Targeted at hydrogen leakage detection in energy vehicles and hydrogen storage stations.

Typical Use Cases

Applications

Hydrogen Energy Vehicles
Hydrogen Storage Stations
Hydrogen Leakage Detectors
Compact OEM Gas Sensors
Official Product Parameters

Technical Specifications

Parameter Specification
Model MP810
Sensor Type Semiconductor flat surfaced sensor
Standard Encapsulation TO-5
Detection Gas H2
Detection Range 100~3000ppm
Loop Voltage (VC) 5.0V±0.1V DC
Heating Voltage (VH) 5.0V±0.1V DC
Load Resistance (RL) Adjustable
Heating Consumption (PH) ≤300mW
Surface Resistance (RS) 0.5KΩ~10KΩ(in 1000ppmH2)
Sensitivity (Rs) 0.2~0.6(H2) Rs1000ppm/Rs100ppm
Standard Test Temperature/Humidity 20℃±2℃;65%±5%RH
Standard Test Circuit VC/VH :5.0V±0.1V
Warm-up Time 7 days