MQ-8 Semiconductor Hydrogen H2 Gas Sensor

The Winsen MQ-8 is a low-cost SnO2 semiconductor hydrogen sensor for 100–1000 ppm H2 detection. It offers good hydrogen sensitivity, a simple drive circuit and long service life for domestic, industrial and portable gas alarms.

BrandWinsen
Sensing PrincipleSemiconductor
Target GasH2
Product TypeSemiconductor Hydrogen Gas Sensor
Hydrogen Sensing for OEM Integration

Product Overview

A widely used SnO2 semiconductor hydrogen sensor for cost-effective leakage alarms and portable gas detectors.

The MQ-8 sensitive material is SnO2, which has lower conductivity in clean air and higher conductivity as hydrogen concentration increases.

A simple external circuit can convert the conductivity change into an output signal related to hydrogen concentration.

Designed for Reliable Integration

Key Features

Good H2 Sensitivity

Designed for hydrogen detection across the specified 100–1000 ppm range.

Simple Drive Circuit

Suitable for cost-sensitive alarm and detector designs.

Long Service Life

Official specifications list a 10-year life span.

Low-Cost Sensor Platform

Common metal-cap semiconductor architecture supports economical designs.

Wide Application Base

Used in domestic, industrial and portable gas detection equipment.

Anti-Interference Characteristics

Official product information notes anti-interference to other gases.

Typical Use Cases

Applications

Domestic Gas Leakage Alarms
Industrial Flammable Gas Alarms
Portable Gas Detectors
Low-Cost H2 Detection
Official Product Parameters

Technical Specifications

Parameter Specification
Model MQ-8
Sensor Type Semiconductor
Standard Encapsulation Bakelite, Metal cap
Target Gas Hydrogen
Detection Range 100~1000ppm(H2 gas)
Loop Voltage (Vc) ≤24V DC
Heater Voltage (VH) 5.0V±0.1V AC or DC
Load Resistance (RL) Adjustable
Heater Resistance (RH) 30Ω±3Ω(room tem.)
Heater Consumption (PH) ≤950mW
Sensitivity (S) Rs(in air)/Rs(in 1000ppm H2)≥5
Output Voltage (Vs) 2.5V~4.0V (in 1000ppm H2)
Concentration Slope (α) ≤0.6(R1000ppm/R400ppmH2)
Standard Test Temperature/Humidity 20℃±2℃;55%±5%RH
Standard Test Circuit Vc:5.0V±0.1V; VH:5.0V±0.1V
Preheat Time Over 48 hours
O2 Content 21%(not less than 18%) O2 concentration effects initial value, sensitivity and repeatability
Life Span 10 years
Size φ19×24.2

Specifications are based on the official Winsen product page or product manual. Confirm the latest datasheet, calibration requirements, communication protocol and mechanical drawing before final product design.