SMX100 Series Miniature Industrial Intelligent Gas Sensor

The SMX100 Series is a compact intelligent gas sensor platform for detecting CO, H2S, O2 or CH4. It integrates the sensing element, signal-processing circuit, UART digital output and diagnostic functions into a low-profile module for easier integration into industrial gas detection equipment.

BrandWinsen
Sensing PrincipleElectrochemical / Catalytic
Target GasCO, H2S, O2, CH4
Product TypeIntelligent Gas Sensor Module
Compact Intelligent Gas Sensing

Product Overview

The SMX100 Series is designed for gas detection equipment that requires compact dimensions, digital communication and simplified system integration.

The series combines a gas sensing element with signal processing and a high-performance microprocessor. Depending on the model, it uses an electrochemical or catalytic sensing principle to detect carbon monoxide, hydrogen sulfide, oxygen or methane.

Its low-profile construction, UART output and integrated diagnostic functions help reduce external circuit design, assembly work and product development time.

Designed for Easier Integration

Key Features

Compact Construction

The approximately 10 mm profile supports integration into space-constrained gas detection equipment.

UART Digital Output

Digital communication simplifies connection to the host controller and reduces analog circuit design work.

Integrated Processing

The sensing element and signal-processing circuit are integrated into one module for easier development.

Diagnostic Functions

Built-in diagnostic and adaptive functions support stable operation and equipment-level management.

Multiple Gas Options

The series includes dedicated versions for CO, H2S, O2 and CH4 detection.

Industrial Integration

Suitable for portable, fixed and embedded gas detection devices used in industrial environments.

Typical Use Cases

Applications

Industrial Safety
Petroleum and Petrochemical
Coal Mines
Warehousing
Utility Tunnels
Robotics and Intelligent Equipment
Series Comparison

Technical Specifications

Parameter SME100-CO SME100-H2S SME100-O2 SMC100-CH4
Detected Gas Carbon Monoxide Hydrogen Sulfide Oxygen Methane
Sensing Principle Electrochemical Electrochemical Electrochemical Catalytic
Measuring Range 0.5–1000 ppm 0.5–200 ppm 0.6–25% vol. 0–100% LEL
Resolution 1 ppm 0.1 ppm 0.1% vol. 1% LEL
Response Time <30 s <30 s <15 s <15 s
Output UART UART UART UART
Operating Voltage 3.0–5.0 V DC 3.0–5.0 V DC 3.0–5.0 V DC 3.0–5.0 V DC
Operating Current <10 mA <10 mA <10 mA <110 mA
Operating Temperature Continuous: -20°C to +40°C; intermittent: -40°C to +60°C
Operating Humidity 15–90% RH, non-condensing
Expected Lifetime 5 years in air

Confirm the latest datasheet, mechanical dimensions, communication protocol and calibration requirements before final product design.

Need More Information About the SMX100?

Contact us for the latest datasheet, model selection support, availability and technical information.

Related Products