ME4-CO Industrial Electrochemical Carbon Monoxide Sensor

The ME4-CO is a constant-potential electrochemical carbon monoxide sensor for industrial and environmental safety equipment. It provides a 0–1000 ppm range, 1 ppm resolution and T90 response of 25 seconds or less.

BrandWinsen
Sensing PrincipleElectrochemical
Target GasCO
Product TypeIndustrial Electrochemical CO Sensor
Gas Sensing for OEM Integration

Product Overview

A standard Ø32 mm industrial CO sensor with stable linear output for harsh-site and environmental monitoring instruments.

The sensor current is proportional to carbon monoxide concentration through controlled electrochemical oxidation.

Its sensitivity, repeatability and anti-interference characteristics suit petroleum, petrochemical, metallurgy, mining and environmental applications.

Designed for Reliable Integration

Key Features

Industrial CO Detection

Designed for petroleum, petrochemical, metallurgy, mining and environmental monitoring.

T90 ≤25 Seconds

Provides a relatively fast response for industrial safety instruments.

Linear Sensor Output

Supports concentration calculation through the external signal-conditioning and calibration circuit.

Stable Repeatability

Designed for consistent response across repeated exposure and recovery cycles.

Anti-interference Design

Provides selectivity for CO detection when used according to the datasheet and application guidance.

OEM Integration

Available for integration into fixed, portable, residential and industrial gas-detection products.

Typical Use Cases

Applications

Petroleum and Petrochemical Sites
Metallurgy Facilities
Mining Safety
Environmental CO Monitoring
Official Product Parameters

Technical Specifications

Parameter Specification
Model ME4-CO
Detected Gas Carbon monoxide (CO)
Detection Range 0–1000 ppm
Maximum Range 1500 ppm
Sensitivity 0.080±0.020 µA/ppm
Resolution 1 ppm
Response Time (T90) ≤25 s
Bias Voltage 0 mV
Recommended Load Resistance 10 Ω
Repeatability <2% of output
Output Linearity Linear
Stability <5% per month
Zero Drift (-20°C to 40°C) 9 ppm
Temperature Range -20°C to 50°C
Humidity Range 15–90% RH
Pressure Range Standard atmospheric pressure ±10%
Dimensions Ø32 × 14.5 mm
Expected Life 2 years in air

Specifications are based on the official Winsen product page or product manual. Confirm the latest datasheet, calibration requirements, communication protocol and mechanical drawing before final product design.

Need More Information About the ME4-CO?

Contact us for the latest datasheet, model selection support, samples and OEM integration information.

Related Products