Gas-Specific Configuration
Configured specifically for hydrogen fluoride with a standard range of 0–10 ppm.
The ZE03-HF is a compact electrochemical module configured for hydrogen fluoride detection. It provides a standard 0–10 ppm range, 0.1 ppm resolution, 3 V TTL UART concentration output and an amplified analog signal for OEM gas-detection equipment.
A pre-integrated electrochemical hydrogen fluoride module with UART and analog outputs for portable and fixed gas detectors.
The module combines a replaceable gas-specific electrochemical sensing element, high-performance microprocessor and built-in temperature compensation in a standard ZE03 platform.
Calibrated concentration data can be read through UART, while the analog output provides the original amplified signal for custom processing and system calibration.
Configured specifically for hydrogen fluoride with a standard range of 0–10 ppm.
Outputs concentration through a 3 V TTL serial interface at a default 9600 baud rate.
Provides an amplified analog output with a listed range of 2–0 V.
Integrated temperature sensing supports compensated gas concentration measurement.
The Ø23.3 × 31.2 mm module simplifies mechanical and electrical platform reuse.
The official manual notes that alternative detection ranges can be customized.
| Parameter | Specification |
|---|---|
| Model | ZE03-HF |
| Detected Gas | Hydrogen Fluoride (HF) |
| Detection Principle | Three-electrode electrochemical |
| Standard Measurement Range | 0–10 ppm |
| Resolution | 0.1 ppm |
| Analog Voltage Output Range | 2–0 V |
| Response Time (T90) | ≤60 s |
| Working Voltage | 5.0±0.1 V DC |
| Working Current | <10 mA |
| Digital Output | UART, 3 V TTL |
| Analog Output | Original amplified sensor signal |
| Default Baud Rate | 9600 bps |
| Operating Temperature | -20°C to 50°C |
| Operating Humidity | 15–90% RH, non-condensing |
| Storage Temperature | -20°C to 50°C |
| Storage Humidity | 15–90% RH, non-condensing |
| Dimensions | Ø23.3 × 31.2 mm |
| Weight | O2 version <25 g; other versions <15 g |
| Expected Life | 2 years in clean air |